About 1,140,000 results
Open links in new tab
  1. Error -63040 Connection Not Established Using LabVIEW FPGA

    Dec 6, 2025 · Error Code -63040: A connection could not be established to the specified remote device. Ensure the device is on and accessible via the network, that the device is not in safe …

  2. NI-RIO Error Code Family - LabVIEW Wiki

    May 7, 2023 · To avoid this error, monitor the FPGA temperature, temperature shutdown threshold, and margin of the FPGA. If necessary, reduce FPGA temperature. The device has …

  3. NI-RIO FPGA Communications Framework Error Codes (FPGA …

    NI-RIO FPGA Communications Framework Error Codes (FPGA Interface) The FPGA Interface functions can return the following error codes for NI-RIO Devices.

  4. FPGA connection error -63040 - NI Community

    Feb 4, 2016 · The default behavior for nodes in LV FPGA is for error terminals to be turned off, since this uses fewer FPGA resources. You can turn error terminals on or off by right-clicking …

  5. NI-RIO, Error -63040 (kRIOStatusRPCConnectionError): - narkive

    In the project manager, I can detect and setup the system with all the modules, however the folders are grayed out. When I drag a module into a vi a new vi crated under the rio in the …

  6. VISA Error 0xBFFF00A7 and NI-RIO Error -63040 Under a …

    Jul 30, 2023 · If you are still seeing a VISA or NI-RIO error after reconfiguring your system, right-click your CompactRIO controller in MAX and select Reboot. If this does not work, try right …

  7. Error Code: -63040 with NI cRIO-9012 - NI Community

    Feb 17, 2015 · Ensure that the device is on and accessible over the network, that the device is not in safe mode, that NI-RIO software is installed, and that the RIO server is running and properly …

  8. i cannot establish a connection my NI-RIO - NI Community

    Apr 23, 2010 · Error -63040 (kRIOStatusRPCConnectionError): A connection could not be established to the specified remote device. Ensure that the device is on and accessible over …

  9. NI-RIO, Error -63040 (kRIOStatusRPCConnectionError):

    Apr 23, 2008 · Ensure that the device is on and accessible over the network, that NI-RIO software is installed, and that the RIO server is running and properly configured. For NI-RIO 2.3 and …

  10. Connect eRIO 9149 to PXIe 8840 controller - NI Community

    Sep 27, 2018 · But when I try to use the second ethernet port on the PXIe to connect to the 9149, I get error -63040 "A connection could not be established to the specified remote device."